99,016 bearing records · search, filter and compare

Find · understand · compare

UCP208 bearing dimensions & suffix variants

Look up recorded dimensions for designations beginning with UCP208. The table retains complete manufacturer designations so special suffixes and different dimensional variants remain visible.

On this page5 sections

Find by measured dimensions

Enter bore d, outside diameter D and width B. Use decimals or inch fractions such as 1/2 or 1 1/4.

For tapered assemblies use total width T; for units or flanged bearings also check the mounting drawing.

Exact model evidence

UCP208 dimensions and recorded technical data

Use the named dimensions for each complete record below. A generic d×D×B answer is not asserted where the base record is missing, dimension symbols are unverified, or the product uses a different geometry such as a housing or thrust assembly. Suffix records are not substituted for a missing base specification.

The numeric series boundary is preserved: a longer number is not included merely because its first digits match. 4 recorded variants are listed. A dash means the value is missing, not zero.

Measurement details

Read the original dimensions for UCP208

Boundary size alone does not describe every ring, shoulder or assembled unit. These tables retain the recorded manufacturer labels, symbols, units and limits for each complete marking. Expand a record to check its detailed measurements.

Important: an approximate value, a minimum or a maximum keeps that qualifier. These reference extracts are not CAD drawings, fit recommendations or replacement approvals.

FAG UCP208 — 11 dimension fields

Plummer block housing unit. Source: Schaeffler medias — FAG; recorded snapshot 2026-09-02.

This record can describe a housed unit rather than a loose bearing. Housing length, bolt spacing and centre height must be checked separately from shaft bore; do not interpret them as bearing outside diameter.

Minimum and maximum mounting dimensions are limits, not nominal bearing dimensions. Check shaft/housing shoulders and fillets against the current drawing before designing a seat.

Bearing and component measurements

MeasurementSource symbolRecorded value
Bore diameterd40 mm
Length totalL184 mm
HeightH298 mm
Distance shaft axisH49.2 mm
Width (base)A54 mm
Height (base)H118 mm
WidthB49.2 mm
Distance of raceway to locking collarS130.2 mm

Mounting limits and abutments

MeasurementSource symbolRecorded value
Distance fixing boreJ137 mm
Width (slot)N17 mm
Length (slot)N121 mm
Open the complete FAG UCP208 record →
FAG UCP208-24 — 11 dimension fields

Plummer block housing unit. Source: Schaeffler medias — FAG; recorded snapshot 2026-09-02.

This record can describe a housed unit rather than a loose bearing. Housing length, bolt spacing and centre height must be checked separately from shaft bore; do not interpret them as bearing outside diameter.

Minimum and maximum mounting dimensions are limits, not nominal bearing dimensions. Check shaft/housing shoulders and fillets against the current drawing before designing a seat.

Bearing and component measurements

MeasurementSource symbolRecorded value
Bore diameterd38.1 mm
Length totalL184 mm
HeightH298 mm
Distance shaft axisH49.2 mm
Width (base)A54 mm
Height (base)H118 mm
WidthB49.2 mm
Distance of raceway to locking collarS130.2 mm

Mounting limits and abutments

MeasurementSource symbolRecorded value
Distance fixing boreJ137 mm
Width (slot)N17 mm
Length (slot)N121 mm
Open the complete FAG UCP208-24 record →
Exact designation reference

Catalogue parameters for UCP208

Choose the complete brand and marking before reading a value. These source-labelled records add dimensions, construction and engineering properties where they were recorded; a shared model number does not establish interchangeability.

Units, ranges and minimum/maximum qualifiers are retained. The data is a dated catalogue reference, not a certified drawing, a complete current specification or an operating approval.

KOYO UCP208 — 18 recorded parameters

Ball bearing unit

Reference: JTEKT / Koyo catalogue; source snapshot 2026-09-02.

KOYO UCP208 is a bearing-unit reference with a nominal bore d = 40 mm. Its catalogue mounting drawing also lists H = 49.2 mm, L = 184 mm, A = 54 mm, J = 137 mm, H2 = 98 mm. These housing and mounting measurements must not be compressed into the d×D×B size of a loose bearing.

Use the exact unit drawing when checking the mounting footprint and shaft position. Symbols such as H and L describe the illustrated unit geometry; their direction must not be assumed to be the same on pillow-block and flange-unit constructions.

Calculated inch drawing values: d = 1.574803 in; H = 1.937008 in; L = 7.244094 in; A = 2.125984 in; J = 5.393701 in; N = 0.669291 in; N1 = 0.826772 in; H1 = 0.708661 in; H2 = 3.858268 in; L1 = 2.086614 in; B = 1.937008 in; S = 0.748031 in. These are conversions of the recorded metric dimensions using exactly 25.4 mm/in, rounded to six decimals, not a separate inch-series unit or a fit tolerance.

The unit number and bore do not prove a cross-brand interchange. Check the insert, shaft locking arrangement, bolt or slot dimensions and any lubrication or sealing details in the same record.

This can be a unit or housing record. Bolt spacing, housing envelope, centre height and the insert identity need separate checks; do not interpret every outside dimension as bearing D.

Values shown are retained from the recorded source. Zero boundary dimensions and zero load ratings from incomplete legacy feeds are withheld rather than presented as usable specifications.

Technical Data

ParameterSource symbolRecorded value
dNot separately recorded40 mm
HNot separately recorded49.2 mm
LNot separately recorded184 mm
ANot separately recorded54 mm
JNot separately recorded137 mm
NNot separately recorded17 mm
N1Not separately recorded21 mm
H1Not separately recorded18 mm
H2Not separately recorded98 mm
L1Not separately recorded53 mm
BNot separately recorded49.2 mm
SNot separately recorded19 mm
Bolt SizeNot separately recordedM14
Basic Load Ratings : CrNot separately recorded29.1 kN
Basic Load Ratings : C0RNot separately recorded17.8 kN
Fatigue Load Limit : CuNot separately recorded0.809 kN
Factor : F0Not separately recorded14.0
Nipple SizeNot separately recorded1/4-28UNF
Open KOYO UCP208 product record →
Brand / full designationNamed dimensions (mm / in)Dynamic C (kN)Static C0 (kN)Reference speed (rpm)Limiting speed (rpm)Mass (kg / g)
FAGUCP208Plummer block housing unit
Bore diameter (d)
40 mm
1.574803 in
Length total (L)
184 mm
7.244094 in
Height (H2)
98 mm
3.858268 in
————1.96 kg1960 g
KOYOUCP208Ball bearing unit
Bore diameter (d)
40 mm
1.574803 in
Recorded outside dimension (D)
—
Catalogue width (symbol unverified)
49.2 mm
1.937008 in
29.1 kN17.8 kN———
FAGUCP208-24Plummer block housing unit
Bore diameter (d)
38.1 mm
1.5 in
Length total (L)
184 mm
7.244094 in
Height (H2)
98 mm
3.858268 in
————2 kg2000 g
FAGUCP208-25Plummer block housing unit
Bore diameter (d)
39.688 mm
1.56252 in
Length total (L)
184 mm
7.244094 in
Height (H2)
98 mm
3.858268 in
————1.96 kg1960 g
Compare recorded seals, clearance, precision and materials

Manufacturer wording is retained. A missing property is not inferred from another brand or a similar suffix.

Brand / designationClosureOriginal precisionClearanceCageMaterialLubricant
FAG UCP208Not recordedNot recordedNot recordedNot recordedGG — Grey cast ironNot recorded
KOYO UCP208Not recordedNot recordedNot recordedNot recordedNot recordedNot recorded
FAG UCP208-24Not recordedNot recordedNot recordedNot recordedGG — Grey cast ironNot recorded
FAG UCP208-25Not recordedNot recordedNot recordedNot recordedGG — Grey cast ironNot recorded

How to compare these values

  • Use the displayed dimension names and original symbols. Housing length L, height H2 and flange width are not bearing outside diameter D. A catalogue width with an unverified symbol must not be assumed to be inner-ring width B or assembly width T. Open the product record for mounting dimensions and geometry.
  • Inch values are calculated from the recorded millimetres using 25.4 mm per inch, rounded to six decimal places. They do not change a metric bearing into an inch-series bearing. Gram values are converted from the recorded mass in kilograms.
  • C and C0 describe different rating conditions. They are not a single safe working-load limit and cannot replace an application load calculation.
  • Reference and limiting speeds are separate catalogue values. The source grease/oil context is shown where recorded. Lubricant, seals, loads, fit, clearance and cooling affect the usable operating speed.
  • A common base number does not prove equivalent seals, clearance, precision, material or interchangeability. Open the full designation for these fields.

Related prefix matches — other model numbers may appear

These discovery results can contain a longer number or a different component. They are not specifications for the requested exact model. Open the complete product to inspect its original geometry.

Check the drawing before substituting

Nominal dimensions are not shaft-fit tolerances. Different variants can add grooves, flanges, wider rings or assembly components. When the table has different dimensions, the complete designation—not the shared prefix—controls.

Reference basis & data limits

Manufacturer terminology is retained in the product records. Technical reference basis: JTEKT Basic Bearing Knowledge (boundary dimensions, tolerance classes and lubrication); NSK Bearing ABCs (lubrication, designations and clearance); NTN technical FAQs (closure codes and component interchange); SKF rolling-bearing selection and maintenance references.

Selection workflows and catalogue grouping are BearingScope editorial aids. Verify the current drawing and application requirements before using a candidate. Missing database information is not converted into an assumed match.

Search the consolidated catalogue

Find, filter and compare bearing model data in one place.

Open model search