PHS25 bearing dimensions & suffix variants
Look up recorded dimensions for designations beginning with PHS25. The table retains complete manufacturer designations so special suffixes and different dimensional variants remain visible.
On this page5 sections ⌄
Find by measured dimensions
Enter bore d, outside diameter D and width B. Use decimals or inch fractions such as 1/2 or 1 1/4.
PHS25 dimensions and recorded technical data
Use the named dimensions for each complete record below. A generic d×D×B answer is not asserted where the base record is missing, dimension symbols are unverified, or the product uses a different geometry such as a housing or thrust assembly. Suffix records are not substituted for a missing base specification.
The numeric series boundary is preserved: a longer number is not included merely because its first digits match. 2 recorded variants are listed. A dash means the value is missing, not zero.
Catalogue parameters for PHS25
Choose the complete brand and marking before reading a value. These source-labelled records add dimensions, construction and engineering properties where they were recorded; a shared model number does not establish interchangeability.
Units, ranges and minimum/maximum qualifiers are retained. The data is a dated catalogue reference, not a certified drawing, a complete current specification or an operating approval.
IKO PHS25 — 13 recorded parameters
Lubrication-type PILLOBALL rod end, insert type with female thread
Reference: IKO PILLOBALL catalogue, K38 (PDF page 5); source snapshot 2026-10-03.
PHS25 has a 25 mm pin bore but an M24×2 female thread: the number 25 does not specify the shank thread. Head diameter is 60 mm and centre-to-end height is 94 mm.
The table concerns the insert-type PHS25 rod end. An EC liner, a male thread or a left-hand version must be checked under its own complete designation. Load capacities are catalogue reference values, not an approved working load.
Manufacturer dimension table
| Parameter | Source symbol | Recorded value |
|---|---|---|
| Pin bore | d | 25 mm |
| Female thread | G | M24×2 |
| Head outside diameter | d2 | 60 mm |
| Housing head thickness | C1 | 22 mm |
| Inner-member width | B | 31 mm |
| Overall length | l4 | 124 mm |
| Bore centre to shank end | h1 | 94 mm |
| Threaded shank length in drawing | l3 | 48 mm |
| Across flats | W | 36 mm |
| Ball diameter | Not separately recorded | 42.862 mm (1 11/16 in) |
| Reference mass | Not separately recorded | 750 g |
| Dynamic load capacity | Cd | 46,200 N |
| Static load capacity | Cs | 72,700 N |
No recorded variant matches these filters. Clear a filter to see other records; no substitute has been inferred.
| Brand / full designation | Named dimensions (mm / in) | Dynamic C (kN) | Static C0 (kN) | Reference speed (rpm) | Limiting speed (rpm) | Mass (kg / g) |
|---|---|---|---|---|---|---|
| IKOPHS25Rod end |
| 46.2 kN | 72.7 kN | — | — | 0.750015 kg750.015 g |
| IKOPHS25LRod end |
| 46.2 kN | 72.7 kN | — | — | 0.750015 kg750.015 g |
Compare recorded seals, clearance, precision and materials
Manufacturer wording is retained. A missing property is not inferred from another brand or a similar suffix.
| Brand / designation | Closure | Original precision | Clearance | Cage | Material | Lubricant |
|---|---|---|---|---|---|---|
| IKO PHS25 | Not recorded | Not recorded | Not recorded | Not recorded | Not recorded | Not recorded |
| IKO PHS25L | Not recorded | Not recorded | Not recorded | Not recorded | Not recorded | Not recorded |
How to compare these values
- Use the displayed dimension names and original symbols. Housing length L, height H2 and flange width are not bearing outside diameter D. A catalogue width with an unverified symbol must not be assumed to be inner-ring width B or assembly width T. Open the product record for mounting dimensions and geometry.
- Inch values are calculated from the recorded millimetres using 25.4 mm per inch, rounded to six decimal places. They do not change a metric bearing into an inch-series bearing. Gram values are converted from the recorded mass in kilograms.
- C and C0 describe different rating conditions. They are not a single safe working-load limit and cannot replace an application load calculation.
- Reference and limiting speeds are separate catalogue values. The source grease/oil context is shown where recorded. Lubricant, seals, loads, fit, clearance and cooling affect the usable operating speed.
- A common base number does not prove equivalent seals, clearance, precision, material or interchangeability. Open the full designation for these fields.
Related prefix matches — other model numbers may appear
These discovery results can contain a longer number or a different component. They are not specifications for the requested exact model. Open the complete product to inspect its original geometry.
Check the drawing before substituting
Nominal dimensions are not shaft-fit tolerances. Different variants can add grooves, flanges, wider rings or assembly components. When the table has different dimensions, the complete designation—not the shared prefix—controls.
Reference basis & data limits
Manufacturer terminology is retained in the product records. Technical reference basis: JTEKT Basic Bearing Knowledge (boundary dimensions, tolerance classes and lubrication); NSK Bearing ABCs (lubrication, designations and clearance); NTN technical FAQs (closure codes and component interchange); SKF rolling-bearing selection and maintenance references.
Selection workflows and catalogue grouping are BearingScope editorial aids. Verify the current drawing and application requirements before using a candidate. Missing database information is not converted into an assumed match.