Electrical bearing damage: pitting, fluting and shaft currents

Electrical discharge across the lubricating film can damage rolling contacts. Fine craters or washboard-like fluting warrant an electrical investigation, particularly in converter-driven equipment. A photograph alone does not establish the current path or prove that an insulated replacement is sufficient.

On this page8 sections
Visual reference · rolling bearings

Inspect the pattern, then test the explanation

Use the illustration to locate the kind of feature being discussed, not to certify the condition of a real part.

Schematic: corrugated bands; crater detail requires magnification. SCHEMATIC · NOT A PHOTO · NOT TO SCALE
Schematic: corrugated bands; crater detail requires magnification.

Electrical erosion / fluting

Discharge through a contact can produce local melting and craters; developed damage may appear as groove-like fluting.

Checks & easily confused patterns

Evidence to investigate

Preserve magnified surface evidence. Qualified personnel should investigate the electrical system and possible current path with appropriate methods.

Do not infer from appearance alone

A striped track or a vibration spectrum alone does not establish electrical damage. Compare mechanical wear, false brinelling and corrosion evidence.

Technical basis: NSK Bearing Doctor, individual damage-type references. Original BearingScope illustrations and investigation prompts, reviewed 4 October 2026. Colour, shape and depth are illustrative; source snapshots are retained in the internal audit.

Understand the protection concept

Insulated bearing or shaft grounding?

Compare where each measure acts. These are reference concepts, not a wiring diagram or an automatic recommendation for your motor.

Insulating interface at the housing side

Outer-ring insulation

  1. Shaft
  2. Steel rolling contacts
  3. Coated outer ring
  4. Housing

A coated ring changes the electrical interface, not the rolling-element material. Check the exact coating and assembly specification.

Reference example
SKF VL0241 / VL0246

SKF 17344 EN, pp. 4–7

Insulating interface at the shaft side

Inner-ring insulation

  1. Shaft
  2. Coated inner ring
  3. Steel rolling contacts
  4. Housing

Coating location matters. SKF describes higher impedance from the smaller inner-ring coating area; this is not a universal motor retrofit approval.

Reference example
SKF VL2071 / VL2076

SKF 17344 EN, pp. 5–7

Insulation within the rolling contact

Hybrid ceramic bearing

  1. Shaft
  2. Steel inner ring
  3. Ceramic rolling elements
  4. Steel outer ring

Ceramic balls and steel rings form a hybrid bearing. A ceramic coating on a steel ring is a different construction. Neither label alone specifies clearance, seals or fit.

Reference example
NSK hybrid ceramic-ball bearings

NSK, Hybrid Bearings with Ceramic Balls

A separate route around bearing contacts

Shaft grounding

  1. Shaft
  2. Grounding contact
  3. Frame / earth
  4. System review

A grounding contact diverts shaft current. Review the motor, coupling and driven equipment together: insulating motor bearings can leave a path through the coupled machine.

Reference example
Grounding brush or ring

ABB, Bearing currents and how to beat them

Highlighted boxes locate the protection concept. The sequence does not predict current direction, quantify leakage or cover every possible bypass path.

Read the complete suffix

6216 HDY2 C3 is NSK’s published decoding example: HDY2 identifies the insulated design; C3 identifies internal clearance. C3 by itself is not an insulation code.

SKF uses different suffixes for inner- and outer-ring coatings. Do not translate an NSK suffix into an SKF or FAG equivalent by matching the base number.

Check clearance separately →

DC resistance is not AC impedance

At high frequency, the coating’s capacitance also matters. A DC test rating does not specify the whole installed drive’s behaviour. Humidity, cleanliness, contact surfaces and mounting conditions affect verification.

Use the exact bearing’s current documentation and test conditions. No voltage limit, coating grade or replacement approval is inferred here from the suffix alone.

Review the complete replacement specification →

Fluting is an inspection finding, not a vibration frequency

NSK describes electrical erosion as arcing damage at lubricated contacts, with melted craters and sometimes corrugated tracks. A vibration peak alone cannot identify that mechanism. Record magnified surface findings and investigate the electrical system as well as mechanical alternatives.

Measurement preparation, not a live test

Keep the questions separate

Shaft-voltage and current measurements require qualified personnel and suitable equipment. This page gives no live-probing instructions. Follow the equipment’s electrical and mechanical isolation procedure before physical inspection.

What was damaged?

Keep motor position, bearing marking and as-found inspection evidence together. Do not replace an observation with a presumed cause.

What was measured?

Shaft-to-frame voltage, bearing current and insulation resistance are different quantities. Record which one the qualified test procedure measures.

What is the current path?

Include both motor bearing positions, the coupling and the driven machine. A motor-only record can miss the path being investigated.

ABB notes that there is no single acceptable shaft-voltage rule for every motor-drive installation. This worksheet records evidence; it never returns a pass/fail verdict.

Entries are not submitted by this tool or saved by it in browser storage. Download before leaving if you need a copy. Without JavaScript, the form and all reference concepts remain readable; browser printing can preserve your entries.

Reference basis and limits
  • SKF, INSOCOAT, publication 17344 EN, May 2017, pp. 4–7: coating positions and electrical test basis.
  • NSK, Ceramic-Coated Insulated Ball Bearings HDY2: construction and designation example.
  • NSK, Hybrid Bearings with Ceramic Balls: hybrid construction.
  • NSK, Electrical Corrosion: damage interpretation.
  • ABB, Bearing currents and how to beat them: system-level paths and measurement limitations.

Reviewed 4 October 2026. These summaries do not reproduce manufacturer drawings or supply an OEM installation procedure. Illustrations are original conceptual interface lists, not photographs of damage. Product availability and exact ratings must be checked for the complete designation.

Observation is not diagnosis

What the evidence can — and cannot — tell you

Observation or contextInterpretation to considerVerification needed
Craters or fluted tracksPossible electrical dischargePreserve magnified images and compare with mechanical wear patterns.
Variable-frequency drive installationElectrical system context mattersRecord drive changes, earthing, cable arrangement and bearing insulation specification.
Repeat damage after bearing replacementThe cause may still be presentReview both bearing positions and the complete current path.

A practical investigation sequence

01

Identify and record

Isolate electrical and mechanical energy before physical inspection. Shaft-voltage/current tests require qualified personnel and suitable instruments.

02

Check the context

Document the exact motor and bearing design, including any insulated ring or hybrid designation. Do not infer insulation from appearance.

03

Verify before acting

Compare the observed damage with mechanical false brinelling, corrosion and lubricant distress. Keep competing explanations open until tested.

04

Keep the decision traceable

Evaluate earthing, electrical insulation and bearing options at system level. Any change must retain the required fits, loads, speed capability and thermal behaviour.

Capture the information a model search cannot guess

Keep this checklist with your inspection or comparison. Checking a box only records that you have collected the item; it does not certify the bearing.

0 of 4 information groups recorded.

Technical basis & editorial scope

Original BearingScope workflow, written for catalogue research and comparison. Manufacturer material is used to check principles, not copied as a product endorsement or substituted for model-specific instructions. Reviewed 1 October 2026.

  • NSK Troubleshooting — Electrical corrosion — Electrical pitting and current damage

Source addresses and collection status are retained in the internal audit. No unpublished dimensions, torque settings, service intervals or interchange approvals are inferred.